Consistency, Compliance, Healthcare Worker Safety

The EVOTECH® ECR is a highly automated reprocessor that offers confidence that endoscope reprocessing is consistent, compliant and safe for healthcare workers.

 

Automation means consistency from start to finish

The automated cleaning cycle*, automated minimum effective concentration (MEC) monitoring, automated leak detection** and automated blockage** detection reduce inconsistencies associated with manual processes.

Easy and accurate recordkeeping for compliance

The EVOTECH® ECR monitors critical cycle information, which is recorded and printed out to help with compliance requirements. Cycle information can also be transferred and stored digitally with ASP ACCESS™, thereby improving and simplifying the process of data management.

Single-shot solution technology for healthcare worker safety

Technology that not only ensures fresh disinfectant and detergent with each cycle but also reduces healthcare worker exposure because no pouring is required.

Individual channel pumps

Each endoscope channel is connected to a separate pump for proper perfusion based on the specific endoscope make and model, providing precise reprocessing parameters.

* Does not eliminate bedside cleaning and may not eliminate manual cleaning; Health Care facilities should follow their own policies and procedures related to the reprocessing of endoscopes to ensure they are complying with all steps recommended by the device manufacturers and are consistent with current standards and guidelines. Not all endoscopes can be automatically cleaned, but may be high-level disinfected. It is recommended that endoscopes with open/closed elevator wire channels be manually cleaned as per manufacturer’s instructions in addition to using the cleaning cycle of the EVOTECH® System. Please refer to the EVOTECH® ECR User Guide and specific connection diagrams for more detailed information regarding cycle capabilities.

**Automatic leak and blockage detection may not apply to all scopes or cycles. Please refer to the EVOTECH® ECR User’s Guide and specific connection diagrams for more detailed information regarding cycle capabilities.

EVOTECH® is a registered trademark of Advanced Sterilization Products, division of Ethicon US, LLC, a Johnson & Johnson company.
© Ethicon US, LLC 2017. All rights reserved. 070889-170411.

*Does not eliminate bedside pre-cleaning. Manual cleaning of qualified medical devices (endoscopes) is not required prior to placement in the EVOTECH® ECR when selecting those cycles that contain a wash stage. Not all endoscopes can be automatically cleaned, but may be high level disinfected in the EVOTECH® ECR. Please refer to the EVOTECH® ECR User Guide and specific connection diagrams for more detailed information regarding these endoscopes.